Molten Steel Temperature Measuring System (WK-800BG)

Short Description:


Product Detail

Product Tags

Specifications

External Setting Function Keys: N1N2 (for setting electronic clock)

Graduation

Items

S

B

R

WRe3/25

Rapid Measuring Temperature range (℃):

1200~1769

1200~1820

1200~1769

1200~1999

Continuous Measuring Temperature Range ()

0~1769

400~1820

0~1769

0~1999

Degree of Accuracy

±0.2

Digital Display

High brightness LED nixie tube is applied, four-digit number, letter height: 54mm

Status Light Display

LED is applied

Working Conditions

Temperature: 0℃~ 50℃Relative Humidity: <85%

Storage Conditions

Temperature: -25~ 70℃Relative Humidity: ≤95%, non-condensate

Power Supply

AC 220V±10%50HZ±5%power dissipation: about 50W

Weight

7kg

External dimensions

370mm×115 mm×290mm

Mounting dimensions

315 mm

Note: The customer-made temperature ranges are available in our company.

Description of Internal and External Setting Function Keys

External Setting Function Keys: N1N2 (for setting electronic clock)

N1 for display selection of month, date, hour and minute; N2 for adjustment, the display number adding one each time it is pressed. The way to adjust time is the same to common electronic clock. Press the clock function, press N1, the indicator displays time (hour and minute) when it is not measuring (not connected with probe). Press N1 again, the indicator displays month, at the same time, the display number adding one each time N2 is pressed. Press N1 once more, the indicator displays hour, at the same time, the display number adding one each time N2 is pressed (the decimal point on top left indicate p.m). Press N1 once more, the indicator displays hour minute, at the same time, the display number adding one each time N2 is pressed. And press N1 once more, the instrument displays the adjusted time, at this time when the thermocouple is connected or the input end of the short circuit instrument automatically shifts into temperature measurement program, it displays the standby mode.

Internal Setting Wire Jumper S2 (select wire jumper according to fast temperature / continuous temperature measurement)

Rapid temperature measurement is used for measurement in molten metal by temperature indicator and fast thermocouple. The indicator automatically displays the status of thermocouple, calculates digital filtering and average value on the bases of judging the temperature platform automatically within its measurement ranges, compensates cold junction, calibrates full scale and amends null point and drifting automatically. The indicator also keeps the temperature balance value on the screen until a new thermocouple is mounted. Electroacoustic implement warns the conclusion of temperature measurement, printer automatically print the time and temperature value and output according to the demand.

Continuous temperature measurement is used for measurement by continuous temperature thermocouple. After filtering the fluctuation of input potential, the indicator displays the corresponding temperature value which is not remained after removing the thermocouple, "--" is displayed.

Note: The factory default is fast temperature measurement. If you need continuous temperature measurement, please disconnect the power, open the cover, find the icon of "continuous / fast", and move the jumper from the "fast" position to the "continuous" location. (As shown below)


  • Previous:
  • Next: